Articles / Home Repair Articles
An airtight belly is very important in heat and cooling efficiency and in preventing water lines from freezing in cold weather. However, it is penetrated by the drain, supply and electrical and gas lines. These openings may or may not have been sea...
28/02/2008 | Print | PDF

Articles / Home Repair Articles
The material placed on top of the floor joists may be plywood, Oriented Strand Board (OSB) or particle board. In any case the joists have glue spread on them and then the 4' x 8' panels of sub flooring are nailed in place. At the time the Sub flo...
28/02/2008 | Print | PDF

Articles / Home Repair Articles
Multiple outlets are run off of a single circuit. As you might expect, a single wire will come out of the main panel and be taken along the side of the house to the front end. This is real easy before the siding is put on. Outlets are then taken ...
28/02/2008 | Print | PDF

Articles / Home Repair Articles
If a single outlet is dead and all the others on that same circuit are still working fine then the outlet itself is damaged or no longer connected properly. Go to the main panel and turn off the breaker to that circuit. Use a circuit tester, or p...
28/02/2008 | Print | PDF

Articles / Home Repair Articles
It is not normal for a breaker to trip on a regular basis and if you have one that does that you have a problem that needs to be found and eliminated. Household circuits, except those going to heavy use appliances like a dryer, range or hot water...
28/02/2008 | Print | PDF

Articles / Home Repair Articles
Double and triple wide mobile homes have a single main panel from where electrical power is distributed. The electrical power to the section(s) without the main panel is concentrated in one or a few points at the marriage line where the parts of th...
28/02/2008 | Print | PDF

Articles / Home Repair Articles
Pilot won't stay lit. Hold down the button, light, hold for a minute, let up. If the pilot goes out, it's the thermocouple. This is a $7 part. Pilot stays on but the furnace doesn't come on, step 1. Do you hear a click when you raise th...
28/02/2008 | Print | PDF

Articles / Home Repair Articles
Less common in newer homes that have plywood or OSB (Oriented Strand Board) subfloors. A big problem in homes with particle board floors. It results when the subfloor gets wet and the sub fl...
28/02/2008 | Print | PDF

Articles / Home Repair Articles
Modern carpet is designed to be stretched 1 to 1 1/2 %. Thus if your home is 16' wide the carpet should be stretched about 2". This can not be done accurately with a kicker. Carpet manufacturers are constantly searching for ways to produce car...
28/02/2008 | Print | PDF

Articles / Home Repair Articles
Manufactured home drywall is is the same as any drywall except for concerns about weight. However, the weight concerns are no minor matter. With Manufactured homes you MUST ALWAYS remember they were carefully engineered to meet the requirements but...
28/02/2008 | Print | PDF

  